20 50 100 200 500 1000 2000 5000 Frequency (Hz) 0 0.2 0.4 0.6 0.8 1 Absorption Coefficient 3 layer 300mm 12" 40 300mm 12" 40 500mm 20" 40 100mm air 600mm
Absorption
Coefficient
Reflection
Coefficient
Impedance
(real)
Impedance
(imag)
Amend
Parameters
Global Parameters
Air temperature: 20°C
Air pressure: 101325 Pa

X Axis: Frequency
Range: 20Hz - 5000Hz
Scale: logarithmic
Resolution: medium

Angle of incidence: 0°
Porous model: Allard and Champoux (1992)
Helmholtz model: Ingard/Allard
Absorber Parameters
Absorber 1 (3 layer 300mm 12")
100mm Porous Absorbent, 3000 Pa.s/m2
100mm Porous Absorbent, 5000 Pa.s/m2
100mm Porous Absorbent, 10000 Pa.s/m2
Rigid backing
Absorber 2 (40 300mm 12")
300mm Porous Absorbent, 5000 Pa.s/m2
Rigid backing
Absorber 3 (40 500mm 20")
500mm Porous Absorbent, 5000 Pa.s/m2
Rigid backing
Absorber 4 (40 100mm air 600mm)
100mm Porous Absorbent, 5000 Pa.s/m2
600mm Air
Rigid backing