20 50 100 200 500 1000 2000 5000 10000 20000 Frequency (Hz) 0 0.2 0.4 0.6 0.8 1 Absorption Coefficient Broadband 16kPa (10cm, 32cm air) Broadband 7kPa (10cm, 32cm air) Broadband 16kPa (16,7cm, 32cm ai Broadband 7kPa (16,7cm, 32cm air
Absorption
Coefficient
Reflection
Coefficient
Impedance
(real)
Impedance
(imag)
Amend
Parameters
Global Parameters
Air temperature: 20°C
Air pressure: 101325 Pa

X Axis: Frequency
Range: 20Hz - 20000Hz
Scale: logarithmic
Resolution: medium

Angle of incidence: random
Porous model: Delany and Bazley (1970)
Helmholtz model: Ingard/Allard
Absorber Parameters
Absorber 1 (Broadband 16kPa (10cm, 32cm air))
100mm Porous Absorbent, 16000 Pa.s/m2
320mm Air
Rigid backing
Absorber 2 (Broadband 7kPa (10cm, 32cm air))
100mm Porous Absorbent, 7000 Pa.s/m2
320mm Air
Rigid backing
Absorber 3 (Broadband 16kPa (16,7cm, 32cm ai)
100mm Porous Absorbent, 16000 Pa.s/m2
15mm Air
50mm Porous Absorbent, 16000 Pa.s/m2
34mm Air
Rigid backing
Absorber 4 (Broadband 7kPa (16,7cm, 32cm air)
100mm Porous Absorbent, 7000 Pa.s/m2
15mm Air
50mm Porous Absorbent, 7000 Pa.s/m2
34mm Air
Rigid backing
Dotted lines indicate that the model used to estimate absorber properties has been used outside of its applicable range. Results may therefore be less accurate than where a solid line is displayed.

Impedance plots are not available for random incidence.