Acoustic Modelling
Porous Absorber Calculator
Helmholtz Absorber Calculator
Multi-layer Absorber Calculator
Username
Password
Forgotten password?
Register
20 50 100 200 500 1000 2000 5000 10000 20000 Frequency (Hz) 0 0.2 0.4 0.6 0.8 1 Absorption Coefficient Broadband 16kPa (20cm, 10cm air) Broadband 16kPa (10cm, 10cm air) Broadband 7kPa (20cm, 10cm air) Broadband 7kPa (10cm, 10cm air)
Absorption
Coefficient
Reflection
Coefficient
Impedance
(real)
Impedance
(imag)
Amend
Parameters
Global Parameters
Air temperature: 20°C
Air pressure: 101325 Pa

X Axis: Frequency
Range: 20Hz - 20000Hz
Scale: logarithmic
Resolution: medium

Angle of incidence: random
Porous model: Allard and Champoux (1992)
Helmholtz model: Ingard/Allard
Absorber Parameters
Absorber 1 (Broadband 16kPa (20cm, 10cm air))
200mm Porous Absorbent, 16000 Pa.s/m2
100mm Air
Rigid backing
Absorber 2 (Broadband 16kPa (10cm, 10cm air))
100mm Porous Absorbent, 16000 Pa.s/m2
100mm Air
Rigid backing
Absorber 3 (Broadband 7kPa (20cm, 10cm air))
200mm Porous Absorbent, 7000 Pa.s/m2
100mm Air
Rigid backing
Absorber 4 (Broadband 7kPa (10cm, 10cm air))
100mm Porous Absorbent, 7000 Pa.s/m2
100mm Air
Rigid backing
Impedance plots are not available for random incidence.