Acoustic Modelling
Porous Absorber Calculator
Helmholtz Absorber Calculator
Multi-layer Absorber Calculator
Username
Password
Forgotten password?
Register
20 50 100 200 500 1000 2000 5000 10000 20000 Frequency (Hz) 0 0.2 0.4 0.6 0.8 1 Absorption Coefficient
Absorption
Coefficient
Reflection
Coefficient
Impedance
(real)
Impedance
(imag)
Amend
Parameters
Global Parameters
Air temperature: 20°C
Air pressure: 101325 Pa

X Axis: Frequency
Range: 20Hz - 20000Hz
Scale: logarithmic
Resolution: medium

Angle of incidence: 0°
Porous model: Allard and Champoux (1992)
Helmholtz model: Ingard/Allard
Absorber Parameters
Absorber 1
Limp Membrane, 2.9 Kg/m2
30mm Air
260mm Porous Absorbent, 7000 Pa.s/m2
Rigid backing
Absorber 2
Limp Membrane, 2.9 Kg/m2
30mm Air
50mm Porous Absorbent, 12000 Pa.s/m2
200mm Air
Rigid backing
Absorber 3
Limp Membrane, 2.9 Kg/m2
30mm Air
270mm Porous Absorbent, 12000 Pa.s/m2
Rigid backing
Absorber 4
Limp Membrane, 2.9 Kg/m2
30mm Air
50mm Porous Absorbent, 12000 Pa.s/m2
220mm Porous Absorbent, 7000 Pa.s/m2
Rigid backing
Absorber 1: Peak absorption at 57.1Hz. Damping=1.35 (high)

Absorber 2: Peak absorption at 63.6Hz. Damping=0.93 (medium)

Absorber 3: Peak absorption at 60.9Hz. Damping=2.13 (high)

Absorber 4: Peak absorption at 57.5Hz. Damping=1.80 (high)