Acoustic Modelling
Porous Absorber Calculator
Helmholtz Absorber Calculator
Multi-layer Absorber Calculator
Username
Password
Forgotten password?
Register
20 50 100 200 500 1000 2000 5000 10000 20000 Frequency (Hz) 0 0.2 0.4 0.6 0.8 1 Absorption Coefficient 250mm rockwool flexi-a 200mm rockwool flexi-a med 5 cm 25cm rockfon 20cm rockfon m/ 5cm luft
Absorption
Coefficient
Reflection
Coefficient
Impedance
(real)
Impedance
(imag)
Amend
Parameters
Global Parameters
Air temperature: 20°C
Air pressure: 101325 Pa

X Axis: Frequency
Range: 20Hz - 20000Hz
Scale: logarithmic
Resolution: medium

Angle of incidence: 45°
Porous model: Komatsu (2008)
Helmholtz model: Ingard/Allard
Absorber Parameters
Absorber 1 (250mm rockwool flexi-a)
250mm Porous Absorbent, 9000 Pa.s/m2
Rigid backing
Absorber 2 (200mm rockwool flexi-a med 5 cm )
200mm Porous Absorbent, 9000 Pa.s/m2
50mm Air
Rigid backing
Absorber 3 (25cm rockfon)
250mm Porous Absorbent, 21400 Pa.s/m2
Rigid backing
Absorber 4 (20cm rockfon m/ 5cm luft)
200mm Porous Absorbent, 21400 Pa.s/m2
50mm Air
Rigid backing
Absorber 1: Peak absorption at 5187Hz. Damping=1.34 (high)

Absorber 2: Peak absorption at 5178Hz. Damping=1.34 (high)

Absorber 3: Peak absorption at 12333Hz. Damping=1.34 (high)

Absorber 4: Peak absorption at 12333Hz. Damping=1.34 (high)