|
|
Global Parameters
Air temperature: 20°C
Air pressure: 101325 Pa X Axis: Frequency Range: 20Hz - 20000Hz Scale: logarithmic Resolution: medium Angle of incidence: 0° Porous model: Komatsu (2008) Helmholtz model: Ingard/Allard |
Absorber Parameters
• Absorber 1
400mm Porous Absorbent, 8200 Pa.s/m2 200mm Air Rigid backing • Absorber 2 Rigid backing |
Dotted lines indicate that the model used to estimate absorber properties has been used outside of its applicable range. Results may therefore be less accurate than where a solid line is displayed.